Carrier · Heat pump troubleshooting
Scenario 2 (default): wired controller with RS485 communication
What is going on
Default method. Uses the KSACN1401AAA wired controller with RS485 between indoor and outdoor units, so the system is fully communicating.
Check in this order
- Use 16 AWG stranded shielded cable for RS485 communication.
- Wire the indoor/outdoor units and wired controller as shown in Fig. 12.
- Set SW1-4 at the air handler as shown in Fig. 13.
- Do not use any 24V terminal at the air handler or outdoor unit in this scenario.
- Use 24V communication only for emergency operation, service or troubleshooting; it is not a standard method.
Applies to: D5CURA with KSACN1401AAA wired controller
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: D5CURA product data, p. 118. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.