24K/36K/48K panel and air inlet grille removal

D5FSCAH / D5FLCAH

What is going on

Procedure to take off the front grille and filter and open the electronic control box cover on the 24K, 36K and 48K sizes. The manual notes the photos may differ slightly from the actual unit.

Check in this order

  1. Push one side of the grille clamp.
  2. Remove one screw, then push the two grille clamps to free the air inlet grille assembly.
  3. Turn the air inlet grille assembly over and pull up the filter.
  4. Remove the 2 screws and take off the electronic control box cover.
  5. Disconnect the connectors of the display board and stepper motor, then release the panel.

Applies to: 24K, 36K and 48K indoor units

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: D5FSCAH / D5FLCAH service manual, p. 66-68. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.