Daikin · Heat pump troubleshooting

S-3E Daikin communicating thermostat wiring

DX6VS / DZ6VS

What is going on

The system uses data lines and 24 VAC power between indoor unit, outdoor unit and thermostat.

Likely causes

  • Wiring errors between the indoor unit, outdoor unit and thermostat
  • Poor communication reliability from loose or unshielded field wiring

Check in this order

  1. Run two wires between the indoor unit and the outdoor unit for data lines 1 and 2.
  2. Run four wires between the indoor unit and the communicating thermostat: data lines 1 and 2, R (24 VAC hot) and C (24 VAC common).
  3. Use the same wire type and gauge as the factory wiring; 18 AWG is recommended.
  4. Consider a high quality shielded, twisted pair cable for data lines to improve communication reliability.
  5. Confirm all wires are secure at each terminal.

Applies to: EEV air handler and EEV cased coil with Daikin One+ communicating thermostat

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin DX6VS / DZ6VS service instructions SiUS612209EA, p. 15. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.