Run system test and charge calculation (inverter systems)
What is going on
The system test is required for inverter systems. The app asks for the charge calculation before the test runs, using the measured line set length and the liquid and suction line diameters. Enter the actual charge weighed in.
Check in this order
- Measure the total line set length.
- Select the liquid and suction line diameter in the app.
- Calculate the required trim charge from the app.
- Enter the actual charge weighed in.
- Verify service valves are open.
- Tap "Run Test".
- Leave the screen if needed; the test keeps running and you can return later.
Applies to: Inverter systems using Daikin One Touch
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin One Touch Smart Thermostat Training Module TRC-10, pp. 29-30. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.