Remove the heat exchanger (1.5 to 3.0 ton HP & AC)
What is going on
Access the heat exchanger by removing the suction grille and left side plate, then unbraze it. Protect the area from the flame.
Check in this order
- Remove the suction grille (1 screw).
- Remove the 4 screws and take off the left side plate.
- Remove any putty near the brazed joints first, since it can burn.
- Put a protective sheet or steel plate in place so the brazing flame cannot reach nearby parts.
- Heat the brazed joints and remove the heat exchanger.
Applies to: 1.5 to 3.0 ton HP & AC
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin SiUS612209EA service instructions, p. 104. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.