Daikin · Heat pump troubleshooting

Remove heat pump wiring at the outdoor unit

DZ6VS

What is going on

Heat pump (HP) 1.5 to 3.0 ton units only. Cut the clamps and disconnect the pressure switch (PS) lead, then disconnect the four way valve and solenoid valve coil leads. Clamps are cut, so new clamps must go back in the same spots.

Check in this order

  1. Cut the 4 clamps and disconnect the PS lead wire at connector X840A.
  2. When reassembling, fix the PS lead wire in the same position with new clamps to prevent malfunction.
  3. Cut the 3 clamps and disconnect the four way valve coil lead wire (connector X800A) and the solenoid valve coil lead wire (connector X28A).

Applies to: 1.5 to 3.0 ton HP models

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin sm-sius612209ea service instructions, p. 88. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.