Carrier · Heat pump troubleshooting

Outdoor unit site selection

D5CURA

What is going on

Locations to avoid and special cases for placing the outdoor unit.

Check in this order

  1. Do not install the unit near an obstacle that blocks the air inlets or outlets.
  2. Do not install where there is heavy dust.
  3. Keep it away from animals or plants that hot air discharge could harm.
  4. Keep it away from any source of combustible gas.
  5. Keep it away from public streets, crowded areas, or places where unit noise will bother people.
  6. In heavy wind, turn the air outlet fan at 90 degrees to the wind direction. Build a barrier in front of the unit if winds are extreme.
  7. Where heavy rain or snow is frequent, build a shelter above the unit without blocking airflow around it.
  8. In cold climates, make the drain hose as vertical as possible so water drains quickly. Slow drainage can freeze in the hose and flood the unit.

Applies to: D5CURA outdoor units

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: D5CURA installation manual, p. 17. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.