Trane · Heat pump troubleshooting

Outdoor temperature shows dashes and SERVICE stays solid

XR402

What is going on

The outdoor display reads dashes and the SERVICE indicator is on steady.

Likely causes

  • Outdoor temperature sensor is open or shorted.
  • Outdoor sensor field wiring is open or shorted.

Check in this order

  1. Replace the outdoor sensor if it reads open or shorted.
  2. Check and repair the outdoor sensor field wiring.

Applies to: XR402 with outdoor sensor

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane XR402 installer's guide 18-HD29D3-4, p. 14. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.