Operation sometimes stops
What is going on
The unit stops intermittently. Check for power interruptions and outdoor temperature limits, then diagnose from the remote.
Likely causes
- Short power failure (2 to 10 cycles) stops operation
- Outdoor temperature outside the operation limit
Check in this order
- Check the power supply for short interruptions; a power failure of 2 to 10 cycles stops operation and the operation lamp goes off.
- Check the outdoor temperature against the operation limit (p. 176).
- Diagnose using the remote controller indication (see p. 96).
Applies to: FTXM-W/V wall mounted inverter pair
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: SiUS042113EA service manual, p. 96. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.