Trane · Heat pump troubleshooting

No heat, heat pump not starting (lockout check)

XR103TCONT103

What is going on

Use a simple click test to check whether the thermostat is calling for heat and whether the furnace is operating.

Likely causes

  • Pilot light not lit on the auxiliary heat source
  • SYSTEM switch not set to HEAT
  • Loose thermostat or system wire
  • Furnace lockout condition
  • Heating system or thermostat needs service

Check in this order

  1. Re-light the pilot if the auxiliary heat has one.
  2. Set the SYSTEM switch to HEAT and raise the setpoint above room temperature.
  3. Check that thermostat and system wires are tight at the terminals.
  4. Listen for a soft click from the thermostat within a few seconds.
  5. If there is no click, perform the reset and check again. If it still does not click, replace the thermostat.
  6. If it clicks, check the furnace or heating equipment itself with the manufacturer or a service technician.
  7. If heat works only intermittently, contact the furnace manufacturer or local service person about the lockout.

Applies to: XR103 / TCONT103 with heat pump and furnace

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane TCONT103 installation and user guide, p. 10. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.