INTELLIGENT EYE drops to energy saving with people in the room
What is going on
The sensor can miss people who are still, or it can wrongly see other things as people. Some of these causes are normal behaviour of the detection method and not a fault.
Likely causes
- Clothing or stillness means the sensor sees no movement.
- Pets, sunlight, fluttering curtains or light reflected from mirrors.
- People are beyond 23 ft (7 m) or outside the sensing angle.
- People stand right at the front of the indoor unit, where the sensor position limits detection.
- NIGHT SET mode does not run while INTELLIGENT EYE is active.
Check in this order
- Confirm the people are inside the sensing range and within 23 ft (7 m).
- Remove or reduce sources of false motion such as curtains and mirrors near the sensor.
- If people are close to the front of the unit, use COMFORT AIRFLOW together with INTELLIGENT EYE.
Applies to: INTELLIGENT EYE models
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin SiUS042113EA service manual, p. 46. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.