Carrier · Heat pump troubleshooting
How to read the heating capacity tables (D5CURA + D5FULA)
What is going on
Pages 88-90 give heating capacity and power input for the 48K and 54K heating tables. Each airflow block lists outdoor dry bulb temperature rows and indoor dry bulb columns from 60.8°F to 75.2°F.
Check in this order
- Find the table for your model and airflow (Table 43 on p. 88, Tables 44 and 45 on pp. 89-90).
- Select the airflow (CFM) block that matches the installed indoor unit.
- Find the outdoor DB row that matches the design outdoor temperature.
- Read TC (total heating capacity, BTU/hr) in the column for the indoor DB temperature.
- Read PI (power input, kW) from the paired column next to TC for the same indoor DB.
Applies to: D5CURA + D5FULA heating performance, 48K and 54K sizes
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: D5CURA Product Data, p. 88-90. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.