Trane · Heat pump troubleshooting

Heat, cool or fan runs constantly

XR103TCONT103

What is going on

A constant run condition usually points to a short in the wiring, the thermostat, or the equipment, or to the fan switch.

Likely causes

  • Short in thermostat wiring
  • Short in thermostat
  • Short in heat, cool or fan system
  • Fan switch set to ON

Check in this order

  1. Set the FAN switch to AUTO.
  2. Check each wire at the terminals for shorts or touching conductors. No bare wire should show beyond the terminal screw.
  3. Reset the thermostat as described in the reset tip.
  4. If the problem continues, ask the system manufacturer or service person how to test the heat/cool system.
  5. If the equipment operates correctly, replace the thermostat.

Applies to: XR103 / TCONT103 heat pump installations

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane TCONT103 installation and user guide, p. 10. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.