Carrier · Heat pump troubleshooting
Evacuation test
What is going on
Check that the system holds vacuum after isolation from the pump.
Check in this order
- Pull the system to the vacuum level specified in the manual.
- Isolate the system from the vacuum pump.
- Confirm pressure does not rise more than 1/2 inch within 10 minutes.
Applies to: Split system field piping
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: D5CURA installation manual, p. 4. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.