Daikin · Heat pump troubleshooting
Emergency mode overview (when wiring or thermostat has failed)
What is going on
Emergency mode is a temporary fallback for when thermostat or indoor-to-outdoor communication cannot be fixed right away. It runs heating or cooling without the communication wires or thermostat. It does not hold a room setpoint, so room temperature depends on the building load. Once wiring or the thermostat is fixed, turn emergency mode off and put the outdoor and indoor units back to normal operation. Emergency mode can be used for these codes if the equipment cannot be fixed immediately: outdoor E51 and Ed2, and EEV indoor E76, E77 and E78. Power cycling may clear those codes but does not fix the cause. In emergency mode the thermostat status menu and outdoor 7-segment displays show no operating status, and the EEV indoor 7-segment display shows EE.
Likely causes
- Broken or disconnected thermostat communication wires (1, 2, R, C)
- Failed thermostat
- Outdoor to indoor communication failure
Check in this order
- Turn off power to all equipment before setting or wiring emergency mode.
- Limit emergency operation to a short, temporary fallback.
- After repair, set all emergency DIP switches back to factory default and restore the thermostat wiring.
Applies to: DX6VS/DZ6VS outdoor with DFVE/CAPE/CHPE EEV units
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin SiUS612209EA service instructions, p. 32. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.