Trane · Heat pump troubleshooting

Display will not come on

XR402

What is going on

The control shows nothing at all.

Likely causes

  • Blown fuse or tripped circuit breaker.
  • Furnace power switch is OFF.
  • Furnace blower compartment door or panel is loose or not seated, so the safety interlock is open.

Check in this order

  1. Replace the fuse or reset the breaker.
  2. Turn the furnace switch to ON.
  3. Reseat the blower door or panel so it engages the safety interlock or door switch.

Applies to: XR402 with a gas or oil furnace

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane XR402 installer's guide 18-HD29D3-4, p. 14. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.