Trane · Heat pump troubleshooting
Display will not come on
What is going on
The control shows nothing at all.
Likely causes
- Blown fuse or tripped circuit breaker.
- Furnace power switch is OFF.
- Furnace blower compartment door or panel is loose or not seated, so the safety interlock is open.
Check in this order
- Replace the fuse or reset the breaker.
- Turn the furnace switch to ON.
- Reseat the blower door or panel so it engages the safety interlock or door switch.
Applies to: XR402 with a gas or oil furnace
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Trane XR402 installer's guide 18-HD29D3-4, p. 14. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.