Daikin · Heat pump troubleshooting
Disconnect the field power and communication wiring and remove the rear plate
What is going on
Field wiring is disconnected at the terminal block. The clamps must be cut and the wires disconnected.
Check in this order
- Cut the 2 clamps.
- Remove the terminal block screws 1 pan head M5 x 12 and 2 pan head M4 x 10.
- Disconnect the external power supply, ground and communication wires from the terminal block.
- Remove the 7 screws and remove the rear plate.
Applies to: 1.5 to 3.0 ton HP and AC outdoor units
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin SiUS612209EB service instructions, p. 83. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.