Daikin · Heat pump troubleshooting

Disconnect PS and valve coil wiring (1.5 to 3.0 ton HP)

DX6VSDZ6VS

What is going on

Heat pump models only. Remove the pressure switch and valve coil leads.

Check in this order

  1. Cut the 4 clamps and disconnect the PS lead at connector X840A.
  2. When reassembling, fix the PS lead in the same position with new clamps.
  3. Cut the 3 clamps and disconnect the four way valve coil lead at connector X800A.
  4. Disconnect the solenoid valve coil lead at connector X28A.
  5. Disconnect the electronic expansion valve coil lead as needed.
  6. When reassembling, fix the leads in the same positions with new clamps to prevent malfunction.

Applies to: 1.5 to 3.0 ton HP models only

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin DX6VS/DZ6VS service instructions SiUS612209EA, p. 88. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.