Daikin · Heat pump troubleshooting
Disconnect HP wiring: PS lead, four-way valve and solenoid valve coils (1.5 to 3.0 ton HP)
What is going on
Heat pump models only. Disconnect the pressure switch and valve coil leads with the unit powered off.
Check in this order
- Cut the 4 clamps and disconnect the PS lead at connector X840A.
- When reassembling, fix the lead in the same position with new clamps.
- Cut the 3 clamps and disconnect the four-way valve coil lead at connector X800A.
- Disconnect the solenoid valve coil lead at connector X28A.
- Note the electronic expansion valve coil lead position for reassembly.
Applies to: 1.5 to 3.0 ton HP models only
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin SiUS612209EB service instructions, p. 88. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.