Carrier · Heat pump troubleshooting

Discharge the electrolytic capacitor before troubleshooting

D5FCFA

What is going on

Capacitors keep a charge after the power is off. Discharge them before touching the board.

Check in this order

  1. Turn off the power and confirm the capacitors are fully discharged.
  2. On units with the discharge position shown in the manual, connect the discharge tool across the + and - terminals of the electrolytic capacitor.
  3. On other models, connect a discharge resistor of about 100 ohm, 40 W (the resistance symbol is garbled in the text, so confirm the value) or a soldering iron plug between the + and - terminals on the reverse side of the outdoor PCB.

Applies to: D5FCFAH outdoor PCB electrolytic capacitor

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Carrier D5FCFAH service manual, p. 28. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.