Choosing the outdoor unit location

D5CURA

What is going on

Pick a site that meets the standards on the page before the outdoor unit is set.

Check in this order

  1. Choose a firm, solid base that will not vibrate.
  2. Place the unit where its noise will not disturb neighbours.
  3. Make sure air can circulate freely and ventilation is good.
  4. In snow areas, raise the unit on risers to the height required by local code, and protect the coil from ice build-up.
  5. Keep the clearances from Table 10 on every side.
  6. Mount the unit at least 2 in (50 mm) above the expected snow depth.

Applies to: Outdoor units

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Carrier D5CURA installation manual, p. 14-16. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.