Replacing the power assembly

WEC Series

What is going on

Replace the power assembly base and upper case with new parts.

Check in this order

  1. Turn off the feedwater supply and disconnect power
  2. Remove the front cover, top cover and power assembly upper case
  3. Remove the 6 connectors from the PCB (AC-INPUT, PUMP, CN2, FAN, DC1-OUT and DC2-OUT)
  4. Remove the 4 screws securing the power assembly base and lift off the base
  5. Install the new power assembly base and secure with 4 screws
  6. Connect the 6 connectors to the PCB (AC-INPUT, PUMP, CN2, FAN, DC1-OUT and DC2-OUT)
  7. Install the new power assembly upper case with 4 screws
  8. Place the top cover on the WEC and connect the 4 connectors to the back of the main panel
  9. Secure the 2 screws to the front and 2 to the back of the top cover
  10. Align the front cover screw holes and secure each side with 2 screws

Applies to: WEC600

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien WEC600 service manual, p. 83-85. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.