Booster pump installation

WEC

What is going on

A booster pump can raise pressure at the point of use. It must not push excess pressure into the WEC.

Check in this order

  1. Use a flow-sensing, automatic-operating booster pump.
  2. Confirm shut-off pressure at zero flow does not exceed 8.5 bar (128 psi).
  3. Install the pump downstream of the carbon block filter.
  4. Install a check valve between the carbon block filter and the booster pump.

Applies to: WEC600

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: WEC Series service manual, p. 15. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.