Navien · General troubleshooting
Display states during normal operation
What is going on
Standby shows no sign on the display. Product state shows one module solid lit while treating water. Product and regeneration state shows one module solid and the other blinking. Regeneration state shows one module blinking with the unit ready. Regeneration line CIP takes about 17 minutes in 5 steps. CIP takes about 2 hours in 14 steps. CIP flushing shows FLU and a countdown after a CIP error. Soft error shows the inspection icon and water still works. Error state shows the inspection icon and an error code, and the unit cannot operate.
Check in this order
- For a soft error, keep the unit running and call Technical Support at 1-800-519-8794 for low-level errors.
- For an error state, use the troubleshooting section (page 52) or call Technical Support at 1-800-519-8794.
Applies to: WEC600
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: WEC Series service manual, p. 32-33. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.