Closing up the WEC600 after part replacement
What is going on
Final fastening and cover installation.
Check in this order
- Secure 2 plastic pins to fix the harness to the top frame, then install 4 screws into the top frame.
- Secure 3 plastic pins to fix the harness to the top frame.
- Place the 2 side covers on the WEC and install 4 screws into the back side.
- Secure 6 screws into the front side of the WEC.
- Place the back cover on the back of the WEC and secure with 11 screws.
- Install the front and top covers as described in the power assembly replacement section (p. 83).
Applies to: WEC600
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien WEC service manual, p. 116. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.