Navien · General troubleshooting

Audible alert and panel notification

WEC Series

What is going on

The unit sounds an alert and shows a notice on the panel when the CIP solution needs refilling, the sediment pre-filter needs replacing, or an error occurs. Pressing OK only silences the alert and does not fix the issue. The alert sounds for 1 minute at 1-second intervals, stops for 10 minutes, then repeats.

Likely causes

  • CIP solution needs refilling
  • Sediment pre-filter cartridge needs replacing
  • An error has occurred

Check in this order

  1. Press OK to silence the alert temporarily.
  2. Refill the CIP solution and perform the filter and CIP reset (see section 3.7 on page 36), or replace the sediment pre-filter and perform the filter and CIP reset.
  3. If an error caused the alert, clear and reset the error using Installer Setting Mode (see section 3.8 on page 38).

Applies to: WEC600

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien WEC service manual, p. 72. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.