Navien · General troubleshooting
Replacing the main panel
What is going on
Swap the main panel while keeping the DIP switch configuration of the old panel.
Check in this order
- Turn off the feedwater supply and disconnect power
- Remove the front cover
- Remove the 2 screws from the back and 2 from the front of the top cover
- Remove the 4 screws and 4 connectors from the back of the main panel, then remove the main panel from the top cover
- Set the DIP switches on the new main panel to match the old one
- Insert the new main panel into the top cover, secure with 4 screws and connect the 4 connectors
- Reassemble the top cover and front cover as in the power assembly procedure
Applies to: WEC600
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien WEC600 service manual, p. 85-86. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.