Navien · General troubleshooting
Replacing the flow switch
What is going on
Flow switch is mounted on the flow switch assembly inside the back cover.
Check in this order
- Shut off the feedwater supply.
- Disconnect power to the WEC.
- Remove the back cover (see Removing the Back Cover, p. 82).
- Unplug the flow switch connector from the harness and remove the flow switch from the flow switch assembly.
- Install the new flow switch on the flow switch assembly and connect its connector to the harness.
- Put the back cover back on the WEC and secure it with 11 screws.
Applies to: WEC600
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien WEC Series service manual, p. 104. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.