Navien · General troubleshooting

Replacing the flow sensor

WEC

What is going on

Remove the back cover and the outlet water pipe assembly to reach the flow sensors, then replace them and reassemble.

Check in this order

  1. Turn off the feedwater supply.
  2. Disconnect power to the WEC.
  3. Remove the back cover (see page 82).
  4. Remove the 4 L-clips from the Y-adapter and T-adapter.
  5. Remove the 2 screws holding the outlet adapter bracket and pull the outlet water pipe assembly out of the water treatment system.
  6. Remove the 4 clips and unplug the 2 flow sensor connectors from the outlet water pipe assembly.
  7. Fit the new flow sensors to the outlet water pipe assembly, secure them with 4 clips, and reconnect the 2 flow sensor connectors to the harness.
  8. Place the water pipe assembly back on the WEC and secure it with 2 screws at the outlet adapter.
  9. Fit the 4 L-clips onto the Y-adapter and T-adapter.
  10. Reinstall the back cover and secure it with 11 screws.

Applies to: WEC600

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien WEC service manual, pp. 94-95. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.