Navien · General troubleshooting
Replacing the circulation pump
What is going on
The circulation pump is grounded to the WEC case and connected through the harness.
Check in this order
- Turn off the feedwater supply and disconnect power
- Remove the 2 screws from both sides of the front cover and remove the cover
- Remove the screw that holds the ground wire to the WEC case
- Remove the circulation pump connector from the harness
- Replace the pump and reassemble in reverse order
Applies to: WEC600
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien WEC600 service manual, p. 88. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.