Replace the flow switch

WEC Series

What is going on

Accessed from the back of the unit after the back cover is removed. The flow switch connects to the harness, and the sensor connector is reconnected after installation.

Check in this order

  1. Turn off the feedwater supply.
  2. Disconnect the power supply from the WEC.
  3. Remove the back cover from the WEC.
  4. Disconnect the flow switch connector from the harness.
  5. Remove the flow switch from the flow switch assembly.
  6. Install the new flow switch on the flow switch assembly.
  7. Connect the flow switch connector to the harness.
  8. Place the back cover on the WEC and secure with 11 screws.

Applies to: WEC600

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien WEC service manual, p. 104. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.