Navien · General troubleshooting

Removing the top cover and power assembly upper case

WEC Series

What is going on

Opens the unit to reach the main panel and power assembly.

Check in this order

  1. Turn off the feedwater supply and disconnect power
  2. Remove the front cover
  3. Remove the 2 screws from the back of the top cover and the 2 screws from the front of the top cover
  4. Remove the 4 connectors from the back of the main panel, then remove the top cover
  5. Remove the 4 screws securing the power assembly upper case and lift it off

Applies to: WEC600

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien WEC600 service manual, p. 82-83. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.