Reinstalling the product/regeneration pipe and flow sensor housing

WEC

What is going on

Refit the water pipe assembly and flow sensor after NDI module replacement.

Check in this order

  1. Insert the O-ring into the Y-adapter and install the product/regeneration water pipe assembly.
  2. Connect the circulation pump outlet hose to the pipe assembly.
  3. Install the 4 clips on the hose and Y-adapters.
  4. Secure 4 screws to fix the flow sensor housing to the NDI modules.

Applies to: WEC600

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien WEC service manual, p. 114. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.