Navien · General troubleshooting
Refill the CIP solution
What is going on
Refill the CIP tank with citric-acid-based Navien CIP solution when the CIP icon blinks. Refill about every 6 months, or sooner based on water quality and usage.
Likely causes
- Low CIP solution means CIP will not work properly, water quality is not guaranteed, and flow drops.
Check in this order
- Wear proper PPE and follow the CIP solution safety data sheet.
- Remove the screws on both sides of the front cover and take off the cover.
- Remove the lid from the CIP tank.
- Insert a funnel into the tank inlet.
- Pour CIP solution slowly through the funnel to avoid spills.
- Remove the container and close the tank lid.
- Close the front cover and tighten both screws.
- Reset the CIP fill level press and hold Back, OK and Next for 3 seconds (see 3.7, p. 36).
- Clean the funnel after use. Do not use any cleaner other than citric acid in the CIP tank.
Applies to: WEC Series CIP tank
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien WEC Series Service Manual, p. 46-47. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.