Piping layout with primary heat pump and optional backup heater

Vitocell 100-E

What is going on

The tank acts as a hydraulic buffer between the heat pump, the backup heat generator and the system loop.

Check in this order

  1. Connect the system return to the tank system return port (H).
  2. Connect the system supply from the highest point port (J) to the system.
  3. Connect the primary heat/cool generator supply to port D and its return to port G at the lowest point.
  4. If a backup heat generator is used, connect its supply to port B and its return to port I.
  5. Leave the injection process plug (F) closed and unconnected.
  6. Verify all piping and componentry in the field; the drawing is conceptual only.

Applies to: Vitocell 100-E MSCA-20-S2 with Vitocal 100-AW AM2V

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocell 100-E MSCA-20-S2 Technical Data Manual, p. 6-7. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.