Navien · General troubleshooting
Piping, freeze protection and securing
What is going on
Corrosion-resistant piping must be used and secured so the tank and lines do not move.
Check in this order
- Use corrosion-resistant pipe materials for the tank connections.
- Apply Teflon tape on all threaded plastic fittings.
- Clamp the piping to the floor to prevent movement.
- Keep the condensate line out of areas exposed to freezing temperatures.
- Protect piping with a shield where personnel traffic could damage it.
- Install unions at each tank connection so the tank can be removed for service.
- Run 1/2" PVC from the vent to the top of the tank where local codes require it.
Applies to: Navien condensate neutralizer tank installation
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien commercial neutralizer installation instructions, p. 1-2. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.