Pipe grounding around the WEC

WEC

What is going on

The WEC section of pipe is electrically insulated, so the piping must be grounded to prevent corrosion.

Likely causes

  • Insulating effect of the WEC section
  • Plastic pipe sections

Check in this order

  1. Ground both ends of the WEC pipe section the inlet side of the sediment filter and the outlet side of the carbon block filter.
  2. If any section uses plastic pipe, add grounding to that section.
  3. Follow NEC 250.104 for all additional grounding.

Applies to: WEC600

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: WEC Series service manual, p. 14. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.