Navien · General troubleshooting

Installing the post carbon block (C/B) filter

WEC

What is going on

Mount and fit the post carbon block filter at the rear of the product water outlet.

Check in this order

  1. Unscrew the filter housing from the head using the supplied wrench.
  2. Fix the mounting bracket to the top of the housing head with screws (B).
  3. Mount the bracket to the wall with screws (A), at least 2 ft (635 mm) above the floor.
  4. Insert the cartridge into the housing and tighten the head with the supplied wrench.
  5. Remove the quick guide from the filter first, or pressure loss and low flow will result.
  6. Stick the Carbon Block Filter (Outlet) label on the bracket.

Applies to: WEC600

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien WEC service manual, p. 18. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.