Installing the drain lines
What is going on
Route the drainwater and NDI freeze prevention lines with a proper air gap.
Check in this order
- Unroll and straighten the LLDPE 1/2in and 1/4in tubes, then cut to length.
- Connect 1/2in fittings to the drainwater outlet and attach the 1/2in tube.
- Connect the 1/4in tube to the NDI module freeze prevention water outlet.
- Keep height at or below 10 ft (3 m) and length at or below 197 in. (5 m).
- Leave a 1-1/2in (40 mm) air gap between the tube end and the drain. Do not put the tube end into the drain.
- Use an L-shaped pipe at the tube end to stop splashing.
- Do not cap or plug the drain lines.
- Make sure the drain has no backflow or backpressure.
Applies to: WEC600
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien WEC service manual, p. 20-21. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.