Installing the buffer tank temperature sensor
What is going on
Mount the tank sensor in the sensor well with the retainer.
Check in this order
- Carefully pull the sensor mounting hardware out of the tank sensor well.
- Mount the sensor on the outside of the sensor spring-clip, not in the centre groove, so it is flush with the front of the clip.
- Push the sensor cabling into the groove of the mounting hardware.
- Push the sensor retainer with sensor into the sensor well as far as it will go.
- For cooling mode only close off the sensor well with the cap after inserting the retainer.
Applies to: Vitocell 100-E MSCA-20-S2
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocell 100-E MSCA-20-S2 installation, service and operating instructions, p. 11. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.