Navien · General troubleshooting

Installing new NDI modules

WEC

What is going on

Fit new NDI modules onto the L-adapters and supporting frame.

Check in this order

  1. Insert an O-ring into each end of the new NDI modules.
  2. Place the new NDI modules on the L-adapters and supporting frames.
  3. Connect the NDI module connectors to the harness.
  4. Secure 2 clips to the L-adapters.
  5. Secure 8 nuts on the bolts to fix each NDI module to the supporting frame.
  6. Secure 4 screws into the side frame brackets.

Applies to: WEC600

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien WEC service manual, p. 113-114. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.