Installing inlet and outlet water lines

WEC

What is going on

Connect the water lines through the bypass and service valves.

Check in this order

  1. Shut off the water supply before connecting the product.
  2. Remove the L-clips, caps and O-rings from the inlet and outlet. Cover the cap with a dry towel while removing it, as some water may come out.
  3. Check the strainer in the inlet adapter. Clean it if it is clogged.
  4. Install the filters, inlet and outlet valves, bypass valve and regulator (if needed) per the piping diagram.
  5. Place O-rings on the inlet and outlet, fit the adapters, and secure them with the L-clips.
  6. Do not over-tighten filter connections and support the piping so it puts no stress on the valves.
  7. Check all connections, then check for leaks as described in section 2.13.

Applies to: WEC600

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien WEC service manual, p. 19-20. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.