Navien · General troubleshooting
Installation checklist before power-up
What is going on
Confirm every item on the installation checklist before the unit is powered. Any item answered No needs the matching installation section fixed first. Troubleshooting is in section 6 (page 52).
Check in this order
- Confirm the WEC is in a suitable location and level (adjust leveling feet).
- Confirm a water bypass is installed for service.
- Check drain tubes have an air gap, length is 197 in. (5 m) or less, and height is 10 ft (3 m) or less.
- Confirm the NDI module freeze prevention drain line is installed.
- Confirm the NaviLink Lite is installed and the CIP tank is full.
- Confirm the power cord is in a properly installed, grounded outlet that meets local code.
- Confirm the system inlet is connected to the cold-water line and feedwater pressure is within specification.
- Confirm the sediment pre-filter and post carbon block filter are installed correctly.
- Confirm a check valve and expansion tank are installed for DHW recirculation or storage tank water heaters.
- Confirm piping at the sediment filter inlet and carbon block outlet is grounded, with extra grounding points on any plastic sections.
Applies to: WEC600
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien WEC Series service manual, p. 24. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.