Connecting two remote control units
What is going on
Up to two remote controls can go on one boiler control, including a Vitotrol 200A with a Vitotrol 300A. Use a field-supplied junction box or KM BUS distributor and keep the total KM BUS cable length within the limit. For the 200A wiring details, refer to the Vitotrol 200A instructions.
Check in this order
- Connect each unit through a junction box or KM BUS distributor as shown in the diagram.
- Keep the total KM BUS cable length to 164 ft (50 m) or less.
- Use the Vitotrol 200A installation instructions for that unit's wiring.
Applies to: Multiple remote controls on one Vitotronic
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotrol 300A installation and service instructions, p. 6. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.