Napoleon · Gas fireplace troubleshooting

White or grey film on glass, logs or firebox

What is going on

A white or grey haze builds up on the glass, the logs and the firebox surfaces of the Napoleon GD70 STARfire direct-vent fireplace (GD70NT-S natural gas, GD70PT-S propane). This is sulphur from the fuel depositing on the surfaces as the gas burns. It is a cleaning matter, not a fault, but confirm the unit is cold before you touch anything.

Likely causes

  • Sulphur in the gas depositing on the glass, logs and firebox surfaces over time

Check in this order

  1. Turn the fireplace off and let it cool completely; never clean the glass while it is hot, because it can shatter or burn you
  2. Clean the glass with a cleaner made for gas fireplace glass, not household glass cleaner or abrasives
  3. Wipe the haze off the logs and firebox lightly with a soft dry cloth, being careful not to disturb the log placement
  4. Tell the owner to clean the glass regularly; deposits left too long can permanently mark the glass
  5. Check that the glass frame is latched properly before relighting

Applies to: Napoleon GD70 STARfire direct-vent fireplace (GD70NT-S natural gas, GD70PT-S propane)

More gas fireplace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Napoleon GD70NT-S / GD70PT-S Installation & Operating Instructions W415-0434, Troubleshooting table, p.25. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.