Napoleon · Gas fireplace troubleshooting
Complete unit shutdown - direct vent
What is going on
Burner (and often pilot) shut down; flame goes blue and see-through before going out - a venting/recirculation fault.
Likely causes
- Leaking seals at vent, door, relief doors, burner or pilot
- Missing 2nd storm collar on vertical terminal
- Blocked termination
- Unsealed inner/outer vent joints
- Vent length/rise outside spec
Check in this order
- If the flame does not go blue first, use the Pilot Failure guide instead.
- Check seals on vent, main door, relief doors and around the burner and pilot assembly; reseal or replace (use the paper gasket test).
- Vertical termination add the 2nd storm collar per the manual diagrams.
- Clear any blockage or obstruction at the terminal.
- Seal all inner and outer vent pipe joints.
- Confirm vent length and rise are within the fireplace and code limits; correct as needed.
Applies to: Napoleon direct-vent gas fireplaces (general service manual flowchart; applies to GD70NT-S/GD70PT-S)
More gas fireplace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Napoleon (Wolf Steel) Service Manual W415-0118, Part 1-3 Troubleshooting, Complete Unit Shutdown, p.8. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.