Napoleon · Gas fireplace troubleshooting

Exhaust fumes smelled in room / occupants get headaches

What is going on

If you smell exhaust in the room, or anyone is getting headaches while the fireplace runs, stop and shut the unit off first. On a direct-vent Napoleon GD70 the combustion system is supposed to be sealed from the room, so fumes in the room mean the fireplace is spilling. The cause may be a leaking door or relief flap seal, a blocked vent or chimney, or on a new unit just paint curing off. Headaches are the thing to take seriously because they can be carbon monoxide. Confirm with a CO test before anyone relights it.

Likely causes

  • Door seal or relief flap seal leaking
  • Blocked chimney or vent
  • Paint curing not yet complete on a new unit
  • Damaged vent joints letting exhaust into the space

Check in this order

  1. Shut the unit off, ventilate the room, and test for CO before further operation, since headaches with a fume smell can indicate carbon monoxide
  2. With the unit cold, check the door seal and the relief flap seal, repair or replace gaskets
  3. Check the vent or chimney for blockage at the terminal and along the run
  4. On a new unit confirm the paint curing (burn-in) process has been completed, the smell should fade
  5. If the smell is not from paint and CO shows up, keep the unit off and call a licensed gas technician
  6. Install or confirm a working CO alarm near the fireplace

Applies to: Napoleon GD70 STARfire direct-vent fireplace (GD70NT-S natural gas, GD70PT-S propane)

More gas fireplace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Napoleon GD70NT-S / GD70PT-S Installation & Operating Instructions W415-0434, Troubleshooting table, p.25. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.