Napoleon · Gas fireplace troubleshooting

Wall switch OFF but main burner comes on when gas knob turned ON

What is going on

Wall switch off, gas knob to ON, main burner lights anyway. Napoleon GD70 STARfire direct vent. The switch is not breaking the circuit, so something is feeding the valve. Short or reversed switch most of the time.

Likely causes

  • Wall switch mounted upside down
  • Wall switch shorted to ground
  • Wall switch wire shorted to ground
  • Faulty gas valve

Check in this order

  1. Look at the switch orientation. Upside down, flip it around.
  2. Check the switch for a ground or short with a meter, power off. Replace the switch if shorted.
  3. Check the switch wire for a short to ground. Repair it or replace the wire.
  4. Switch and wire good, valve is the culprit. Replace the gas valve, and have a licensed gas tech do it.
  5. Leak test the new connections and confirm the burner shuts off with the switch before you leave

Applies to: Napoleon GD70 STARfire direct-vent fireplace (GD70NT-S natural gas, GD70PT-S propane)

More gas fireplace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Napoleon GD70NT-S / GD70PT-S Installation & Operating Instructions W415-0434, Troubleshooting table, p.26. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.