SIT 820 Nova millivolt valve: pilot will not stay lit

What is going on

The pilot lights while the knob is held but goes out when released, or drops out later.

Likely causes

  • Wrong inlet pressure
  • Pilot flame too small or not on the thermocouple/thermopile
  • Thermocouple or thermopile not fully seated, dirty or failed
  • Failed safety magnet in the valve
  • Wrong or blocked pilot orifice

Check in this order

  1. Relight and hold the knob in for 30 seconds before releasing.
  2. Check the thermocouple and thermo-generator are fully inserted in the pilot; thermocouple tight in the valve = hand tight plus 1/4 turn with a wrench. Clean the tips (upper 3/8 in.) with very fine emery cloth.
  3. Millivolt Plus open-circuit thermocouple voltage should be 18-28 mV; under 14 mV = replace the thermocouple.
  4. Safety magnet (mV Plus) hold the pilot button, reconnect the thermocouple, measure between the solder button on the magnet and the valve body. Above 6 mV (vented) or 8.5 mV (unvented) and the magnet will not hold = replace the valve. Closed-circuit reading equal to open-circuit = open coil, replace the valve.
  5. Millivolt system remove the operator wires and measure TPTH to TP; above 110 mV and the magnet will not hold = replace the valve.
  6. Replace a blocked or wrong pilot orifice with the exact one for the appliance and gas type.

Applies to: Fireplaces and gas logs with SIT 820 Nova MV / Millivolt Plus valves

More gas fireplace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: SIT 820 Nova MV Troubleshooting Guide; SIT Gas Control Valve troubleshooting flow chart (Fireparts). Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.