All brands · Gas fireplace troubleshooting
Flameworks millivolt valve: pilot outage or burner will not come on
What is going on
Fireplace or heater with a Flameworks millivolt or 3 V gas valve: pilot will not stay lit, or the main burner will not come on.
Likely causes
- Pilot flame not covering the thermocouple/thermopile tip
- Low thermocouple or thermopile output
- Weak automatic pilot magnet
- Failed valve operator
- Too much resistance in thermostat leads
Check in this order
- Lighting knob to PILOT, push and light, hold 2 minutes before releasing. If the pilot lights without pushing the knob, replace the valve.
- Pilot flame should cover the upper 3/8 in. of the thermocouple/thermopile tip; adjust with the pilot screw, never with the knob.
- Thermocouple (non-millivolt) closed-circuit output under 8 mV = replace the thermocouple. Magnet check: a good magnet stays latched for a drop of at least 5 mV from the stabilized reading, otherwise replace the valve.
- Millivolt thermopile output should be 250-750 mV. Test A (terminals 2 & 3, thermostat closed) above 100 mV but valve not opening = replace the valve operator. Test B (1 & 3, thermostat closed) below 325 mV = clean/tighten connections, adjust pilot, else replace the thermopile. Magnet is good if it stays latched down to 120 mV or less.
- Test C (thermostat circuit) too high = clean/tighten thermostat leads, shorten them or use heavier wire, or replace the thermostat. Max wire: 14 ga 100 ft, 16 ga 64 ft, 18 ga 40 ft, 20 ga 25 ft, 22 ga 16 ft.
- Do not exceed 1/2 psi (14 in. w.c.) inlet. Replace any valve that has been under water or will not shut off.
Applies to: Appliances with Flameworks millivolt or 3 V gas valves
More gas fireplace guides
- Maxitrol GV60 remote valve: fireplace will not light or respond
- Proflame (SIT DFC): fan, AUX outlet, split flow or OFF command not working
- Proflame (SIT DFC): pilot lights but main burner will not light or drops out
- Proflame (SIT DFC): pilot will not light or DFC locks out
- SIT 820 Nova millivolt valve: main burner will not come on or will not cycle
- SIT 820 Nova millivolt valve: pilot will not light
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Flameworks Gas Valves Installation Manual (millivolt / 3 V), p.2-4. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.